Planning tool

Camp & Facility Space Planner

Functional area requirements for accommodation, medical, command, dining, storage, and sanitation — mapped to modular units and shelter options.

Worked example with default inputs
FunctionBasisArea
Accommodation 50 × 3.5 m² 175 m²
Clinical / inpatient 8 × 8 m² 64 m²
Command / office 6 × 5 m² 30 m²
Dining / mess 24 × 1.2 m² 29 m²
Storage / logistics 40 × 1 m² 40 m²
Sanitation 3 toilets × 3 m² 9 m²
Total functional area347 m²
Z-Fold units (if rigid modular units are used)≈ 26 units (14.6 m² each) → ≈ 3 × 40HQ containers, 117 crew-hours installation
Aluminum-frame option6 m span, ≈ 58 m total length

Site environment check

Shelter classPublished ratingYour site
Inflatable shelters — standard class (relief, firefighting, security) -25°C to +70°C · wind ≥ Beaufort 8 · snow ≥ 20 kg/m² · altitude ≤ 2000 m Enter site conditions
Inflatable shelters — medical class -25°C to +70°C · wind ≥ Beaufort 10 · snow ≥ 30 kg/m² · altitude ≤ 2000 m Enter site conditions
Inflatable shelters — high-pressure air-beam class (maintenance, hangar, logistics) -43°C to +50°C · wind ≥ Beaufort 8 · 100 mm loose snow accumulation Enter site conditions
Aluminum frame shelters (A-Frame / Arch) -30°C to +70°C Enter site conditions
Z-Fold emergency modular unit wind ≥ Beaufort 8 (Grade 8 reference) Enter site conditions

Ratings are quoted exactly as published for each product class; classes intentionally differ. “Confirm” marks conditions our engineering team verifies against the final specification and anchoring method.

Indicative planning figures — all SUNSHINE shelters and modular units are made to order, so unit counts, layouts, and anchorings are proposed in a project-specific quotation. Accommodation and sanitation inputs follow Sphere Handbook 2018 minimum standards.

Standards and sources

Accommodation and sanitation figures follow the Sphere Handbook 2018 minimum standards: 3.5 m² of covered living area per person for initial disaster response, rising to a 4.5–5.5 m² band in cold climates, and tiered toilet-to-person ratios of 1:50 in the first days, 1:40 for short-term operation, and 1:20 for longer-term operation. Clinical, command, dining, and storage figures are indicative industry planning values — they are honest starting points, and our engineering team confirms them against your medical workflow, rations model, and cargo profile in the quotation.

From areas to units

Because every SUNSHINE shelter is made to order — footprints run from a few square metres to several hundred — the planner deliberately outputs areas and unit requirements rather than a fictitious tent count. Three ways to cover the computed area are shown:

  • Z-Fold emergency modular units — approximately 14.6 m² of enclosed floor area each, shipping up to 10 folded units per 40HQ container and installing in roughly 4–5 hours with a crew of 3–4. The planner totals the units, containers, and crew-hours.
  • Aluminum-frame shelters — A-Frame and Arch tents span up to 6 m with modular, extendable length; the planner converts your area into an indicative total length at that span.
  • Made-to-order inflatable tents — sized exactly to the function list you entered, quoted by dimension and specification.

The site environment check

Enter the site’s temperature extremes, design wind, snow load, and altitude, and the planner compares them against the published ratings of each shelter class. Ratings are quoted exactly as published per product class — classes intentionally differ, and where a figure is not published, or is expressed on a different basis (for example snow as accumulation depth), the result says so instead of guessing. Anything marked for confirmation is checked by our engineers against the final specification, anchoring method, and local code before it appears in a quotation.

FAQ

Frequently asked questions

Quick answers about this tool and how a calculation becomes a quotation. Can't find your answer? Send us your inputs — our engineering team replies within 24 hours.

Planning tool
Baoding Sunshine Enterprises Ltd.
Accommodation and sanitation figures follow the Sphere Handbook 2018 minimum standards: 3.5 m² of covered area per person (4.5–5.5 m² in cold climates) and tiered toilet-to-person ratios. Other functions use indicative industry planning figures confirmed per project.

Turn the numbers into a proposal.

Send us your inputs and requirements — our engineering team replies with a project-specific quotation and drawing.