Multi-purpose logistics shelter

Logistics Support Tent

Configurable shelter for accommodation, storage, command, medical, dining and guard-service use.

Customizable to specification

Puncture resistance
≥ 1,000 N
Rated pressure
0.2 MPa
Operating temperature
−43°C to +50°C
Storage temperature
−55°C to +70°C

Overview

Applications

camping accommodation, ammunition storage, small command post, guard service, medical, warehouse, dining, and other purposes.

Applications in field logistics

Relief corridors and remote supply points need covered floor space faster than any permanent build can deliver. These tents form the sorting and dispatch heart of forward hubs: pallet lanes under cover, manifest desks out of the dust, and segregated bays for damaged or quarantined stock. The inflatable structure ships compact and raises without cranes, so a hub can follow an operation as it moves. Fabric literacy pays off here, and the PU coated polyester fabric guide covers how to read the material line on a datasheet.

Cold-chain and desert corridors stress equipment in opposite directions, and the operating band of this category, from -43°C to +50°C, is written for both. Arctic supply lines use the same shelter as desert staging grounds, with anchoring and interior layout adapted to each, because frozen ground and desert ballast place different demands on the same rated envelope. Procurement teams evaluating comparable military-style structures often start with How to Choose a Military Inflatable Tent and 5 Things to Check Before Buying a Military Tent (2026).

Breaking down the specification numbers

The rated pressure of 0.2 MPa, equal to 200 kPa, is the pressure ceiling the beam system is engineered around. Treat the figure as a design limit on the datasheet, not a number to chase with the inflator; the inflation practice for each model follows the instructions issued with it.

Puncture resistance of at least 1,000 N describes the pointed loading the beam wall takes before penetration, the failure mode that matters around pallet corners, fork tips and cargo hooks. The storage temperature range of -55°C to +70°C is deliberately wider than the operating band of -43°C to +50°C: a packed tent tolerates unheated depots and hot containers, while the erected structure serves within the narrower span. Fabric behaviour under standard test methods such as ASTM D6614 gives buyers a common reference when comparing membranes across suppliers. Shipments into Saudi markets answer to technical regulations issued by SASO.

Frequently asked procurement questions

Do we need special inflators for a 0.2 MPa system?

The 0.2 MPa rating is a design ceiling, equal to 200 kPa, and routine inflation follows the instructions issued with each model rather than pushing toward the limit. What matters is that pump and gauge read in the matching range and stay serviced. Confirm compatible inflator models with the SUNSHINE engineering team.

How does the fabric handle sharp cargo?

The beam wall resists puncture loads of at least 1,000 N, which covers the knocks of everyday freight handling. The figure is a material property, not a licence to drag pallets against the structure. Ground mats and standoff barriers keep sharp traffic away from the envelope.

Can we store units in unheated winter depots?

Yes, within the storage range of -55°C to +70°C, which is deliberately wider than the operating span. A unit that has wintered in a cold store gets inspected and conditioned before deployment at deep cold. The engineering team can outline the pre-deployment check sequence.

Specifications

ProductLogistics Support Tent
SpecificationMulti-purpose logistics shelter
ItemSpecification
Structural Performance
Air Beam Puncture Resistance≥ 1000 N
Rated Working Pressure0.2 MPa
Environmental Adaptability
Operating Temperature-43°C to +50°C
Storage Temperature-55°C to +70°C
Waterproof PerformanceRainfall ≥ 2 mm/min: No leakage for 3 h; No dripping for 5 h
Salt Spray Resistance150 h without discolouration, chalking, or cracking; suitable for coastal environments
Snow Load CapacityWithstands 100 mm loose snow accumulation
Wind Resistance≥ 20.7 m/s (Beaufort Scale 8)
Thermal InsulationTriple-layer system: outer fabric + insulated inner tent + air insulation layer; compatible with HVAC systems
Reliability & Durability
Continuous Operation≥ 60 days with single inflation
Designed Service Life≥ 5 years

Video

Small Tent, Big Capability — 62 m² Inflatable Shelter Deployment Test

Real-time deployment of a 62 m² compact high-pressure inflatable shelter: unpack to fully inflated, interior space walkthrough, and complete repack with a minimal crew.

Only a static thumbnail loads before playback — the YouTube player loads after you select play, subject to the Google Privacy Policy.

Customization

All specifications — including dimensions, materials, coating, colour, and accessories — can be tailored to your project requirements. Flexible MOQ from prototype to full-scale production; standard custom projects take 15–30 days from design confirmation to sample delivery.

Field Shelter Solutions — common questions

Our shelters are field-tested from -43°C to +50°C, with frame and fabric specified for the deployment climate (arctic, temperate, desert, or tropical).

Ready to discuss your requirements?

Engineering team responds within 24 hours.

WhatsApp

Request a Quote

Tell us about your project

Our engineering team reviews every inquiry and responds within 24 hours. No resellers, no commission — you speak directly with the source manufacturer.

B2B Project Enquiry

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.